When the cell located strong electric field,
transmembrane potential is getting increase by short pulse(1§Á
square pulse) and makes whole or destroy(die).
Figure 1. Electroporation of cell membrane
due to compression when exposed to high intensity electric
fields.
(A) in the absence of electric field E
= 0
(B) in the presence of electric field E <
Ec
(C) in the presence of electric field E >
Ec
(D) in the presence of electric field E >>
Ec
Figure 2. Square wave pulse
generating circuit
2. High voltage pulse sterilization system
In order to develope high voltage pulse
sterilization technology, we made bench scale high voltage
pulse generator to use exponential pulse wave.
Small scale pilot system
Load voltage
|
50 kV
|
Pulse width
|
1¡5 §Á
|
Peak load currents
|
2000 A
|
Pulse repetitive rate
|
3 ¡ 5000 Hz
|
Average power in Load
|
40 kV
|
Fig. 3. Small scale pilot system
|